Simulation of ultra sensitive pressure sensor based on long range surface plasmon resonance.
Ali Jandaghian , Ali Lotfalian * 1, Ayda Aray , Mojtaba Arjmand , Ezodin Mohajerani , Hossein Saghafifar
Abstract:   (2051 Views)
In this study, a pressure sensor based on surface plasmon resonance and also the relations of the change in refractive index that is affected by the change of pressure is numerically investigated. The use of long range surface plasmon resonance will be more sensitive so the effect of metal and dielectric layer thickness on the operation of this type of sensor and optimum thickness is analyzed. For metal, the optimal thickness of 15 nm were obtained. For structure with optimal parameters, the sensor is able to vary the reflectance from 0.035 to 0.765 by applying a pressure as low as 0.96 kPa. The sensitivity of sensor is calculated about 8.6×〖10〗^(-6) deg/MPa.
Keywords: Long rang surface plasmon resonance, Polymer, Pressure sensor, Sensitivity .
Full-Text [PDF 557 kb]   (557 Downloads)    
Type of Study: Research | Subject: Special
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA code


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

jandaghian A, lotfalian A, aray A, arjmand M, mohajerani E, saghafifar H. Simulation of ultra sensitive pressure sensor based on long range surface plasmon resonance.. ICOP & ICPET. 2015; 21 :933-936
URL: http://opsi.ir/article-1-825-en.html


Volume 21 - Back to browse issues page
انجمن اپتیک و فوتونیک ایران Optics and Photonics Society of Iran
Persian site map - English site map - Created in 0.05 seconds with 30 queries by YEKTAWEB 3781