Association Mission
The mission of the association is to advance the creation, communication and application of knowledge to benefit society and improve people's lives.  
Membership
Contact Us
                    Download citation: 
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:
 
					
 
                    
					
                    
                    BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:



 Afsharan H,  tajalli H,  Rashidi M R,  Mollabashi M,  Navaeipour F. Fabrication of Electrochemilumonescese biosensor using Ru-Si@Au nanocomposite.  ICOP & ICPET _ INPC _ ICOFS 2015; 21 :173-176
URL: http://opsi.ir/article-1-713-en.html
  
                    URL: http://opsi.ir/article-1-713-en.html
                     Hadi Afsharan *1  
   ,  Habib Tajalli2
,  Habib Tajalli2  
   ,  Mohammad Reza Rashidi3
,  Mohammad Reza Rashidi3  
   ,  Mahmood Mollabashi1
,  Mahmood Mollabashi1  
   ,  Farzaneh Navaeipour1
,  Farzaneh Navaeipour1  
   
                    
                     
   ,  Habib Tajalli2
,  Habib Tajalli2  
   ,  Mohammad Reza Rashidi3
,  Mohammad Reza Rashidi3  
   ,  Mahmood Mollabashi1
,  Mahmood Mollabashi1  
   ,  Farzaneh Navaeipour1
,  Farzaneh Navaeipour1  
   
                    
                    1- iran university of science and technology 
2- tabriz university
3- tabriz university of medical sciences
                    2- tabriz university
3- tabriz university of medical sciences
                    Abstract:       (5653 Views)
                    
                    
                    In this paper, first step to using of Ru(bpy)32+  as a luminophore in fabrication of an ElectroChemiLuminescence biosensor for detection of biomolecules,which is,increasing of the sensitivity of the biosensor by using of  Ru-Si @ Au nanocomposites instead of Ru(bpy)32+ ,  has been investigated. Also optimization of concentrations of Ru-Si @ Au nanocomposite and TPrA as the main and effective materials for detection of biomolecularsare has been discussed. So different concentrations of these materials without presence  of biomolecules produced ,and emitted photons were measured.
                    
                    
                    
                    Keywords:  biosensor, ElectroChemiLuminescence (ECL), Ru-Si@Au nanocomposite, photomultiplier (PMT), Au nanoparticles
                    
                    
                    
                    
                    Send email to the article author
                    
                    | Rights and permissions | |
|   | This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. | 

 
  
  
 