ghasemi E, jelvani S, montazerolghaem M, shayganmanesh M, esmaeilpour D. The effects of anode electrode configuration on the performance of fast flow CW CO2 laser. ICOP & ICPET _ INPC _ ICOFS 2015; 21 :529-532
URL: http://opsi.ir/article-1-670-en.html
URL: http://opsi.ir/article-1-670-en.html
Elaheh Ghasemi * 1, Saeed Jelvani2 , Mohsen Montazerolghaem2 , Mahdi Shayganmanesh1 , Davood Esmaeilpour2
1- IUST
2- NSTRI
2- NSTRI
Abstract: (4197 Views)
In this work, the effect of the anode electrodeconfiguration on the performance of a fast transvers flow CW CO2 laser is investigated.The optimum configuration consists of a 15pins stainless steel as the anode electrode and a water-cooled copper tube of 10mmouter diameter, 15cm length as the cathode. For the gas ratio of CO2: N2: He ≡ 1: 2.5:1, total pressure of 180 mbar and a discharge gap of1.5cm, the output power of 17.2Wis achieved. Also, the highest value of electro-optical efficiency for the laser is estimated about 5.81%.