Abstract: (6964 Views)
Abstract- In this paper, we determinate the temperature profile of a copper vapor laser (CVL) when its dielectric mirrors are replaced with metallic mirrors. The plasma is produced in CVL tube of 510.6 nm and 578.2 nm wavelengths, and with pulse width of 25-30 ns at about 10-2 Torr pressure. The experiment condition was preserved in local thermodynamic equilibrium. The temperature is obtained from the Boltzmann plot method for each cavity mirror. We examined the method for two different cases, copper coated on BK7 substrate, and the laser's fabric mirrors.