Numerical Investigation of the Electric Field in the TEA CO2 Laser Using Successive Over Relaxation Method
Nahid Jahanian * 1, Majid Aram , Nader Morshedian , Ahmad Mehramiz
Abstract:   (938 Views)

In this paper the distribution and non-uniformity of electric field resulted of the main electrodes and pre-ionization in the TEA CO2 laser is investigated using SOR method.  Also the difference in uniformity of electric field related to Corona and Spark Array pre-ionization methods are compared. The results show that the deviation of the electric field in Spark Array Model is more than Corona model. Besides, it has been shown that using electrodes with curved active area edges the field deviation can be reducedd to acceptable level.

Keywords: Carbon dioxide laser pulse width, Numerical simulation of electric field, Pre-ionization, S.O.R, Electrode, Corona and Spark Array pre-Ionization
Full-Text [PDF 482 kb]   (267 Downloads)    
Type of Study: Research | Subject: Special
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA code


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Jahanian N, Aram M, Morshedian N, Mehramiz A. Numerical Investigation of the Electric Field in the TEA CO2 Laser Using Successive Over Relaxation Method. ICOP & ICPET. 2017; 23 :949-952
URL: http://opsi.ir/article-1-1343-en.html


Volume 23 - Back to browse issues page
انجمن اپتیک و فوتونیک ایران Optics and Photonics Society of Iran
Persian site map - English site map - Created in 0.05 seconds with 30 queries by YEKTAWEB 3781