In this research, a tapered optical fiber was fabricated using single-mode optical fiber by a stretch and flame method. Then, using a magnetic sputtering method, 20 nm of palladium metal was deposited as an absorbent layer on the fiber. Spectral displacement of each fiber for various percentages of hydrogen gas (0 to 8%) was recorded in the room temperature by the optical spectral analyzer and the spectral sensitivity of 1/17×105 nm/RIU was gained. It is shown that the sensitivity is increases by increasing the taper angle.