Association Mission
The mission of the association is to advance the creation, communication and application of knowledge to benefit society and improve people's lives.
Membership
Contact Us
Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:



Nouri Jouybari S, Movahedi M, Latifi H. Temperature Sensitivity Measurement of Brillouin Frequency Shift using Coherent Detection. ICOP & ICPET _ INPC _ ICOFS 2015; 21 :1281-1284
URL: http://opsi.ir/article-1-603-en.html
URL: http://opsi.ir/article-1-603-en.html
1- University of Mazandaran
2- Shahid Beheshti University
2- Shahid Beheshti University
Abstract: (3572 Views)
In this article, Brillouin frequency shift of a single mode fiber is measured using coherent detection technique. A reference light pumped Brillouin laser instead of reference light is used as local oscillator in coherent detection technique to decrease the beat signal frequency. As a result, the frequency of beat signal is decreased from 11GHz to 1GHz. Then, temperature effect on Brillouin frequency shift is measured and the sensitivity of 1.05 was obtained.