Association Mission

The mission of the association is to advance the creation, communication and application of knowledge to benefit society and improve people's lives.  

Legal Members

 

Membership

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Jahanian N, Aram M, Morshedian N, Mehramiz A. Numerical Investigation of the Electric Field in the TEA CO2 Laser Using Successive Over Relaxation Method. ICOP & ICPET _ INPC _ ICOFS 2017; 23 :949-952
URL: http://opsi.ir/article-1-1343-en.html
Abstract:   (2648 Views)

In this paper the distribution and non-uniformity of electric field resulted of the main electrodes and pre-ionization in the TEA CO2 laser is investigated using SOR method.  Also the difference in uniformity of electric field related to Corona and Spark Array pre-ionization methods are compared. The results show that the deviation of the electric field in Spark Array Model is more than Corona model. Besides, it has been shown that using electrodes with curved active area edges the field deviation can be reducedd to acceptable level.

Full-Text [PDF 482 kb]   (896 Downloads)    
Type of Study: Research | Subject: Special

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.