[Home ] [Archive]   [ فارسی ]  
:: Volume 21 - ::
ICOP & ICPET 2015, 21 - : 945-948 Back to browse issues page
Simulation of side-polished fiber optic pressure sensor based on surface plasmon polariton
Ali Lotfalian * 1, Ayda Aray 1, Mojtaba Arjmand 1, Hosein Saghafifar Dr1
1- malek-ashtar
Abstract:   (2024 Views)
According to pressure induced refractive index variation, a pressure sensor based on surface plasmon polariton has been simulated using transfer matrix method. In order to study of important parameters on operation of this kind of sensor, the effect of clad and metal thickness has been simulated. Results show that the optimum metal thickness is about 45 nm. It is found that for polymer with 0.2 MPa Young’s modulus, variation of wavelength versus pressure is about 9000 nm/MPa.
Keywords: Pressure sensor, Surface plasmon plariton, Young’s modulus
Full-Text [PDF 576 kb]   (628 Downloads)    
Type of Study: Research | Subject: Special
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA code


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

lotfalian A, aray A, arjmand M, saghafifar H. Simulation of side-polished fiber optic pressure sensor based on surface plasmon polariton. ICOP & ICPET. 2015; 21 :945-948
URL: http://opsi.ir/article-1-823-en.html