1- Laser and Plasma Research Institute, Shahid Beheshti University
Abstract: (1411 Views)
Birefringence measurement is an important properties of optical material in optical area. Compared with conventional birefringence measurement method, a novel birefringence measurement method of ferro-fluid is presented using non-adiabatic tapered fiber optic in fiber loop mirror configuration. Simulation and experiment were done to prove the effective of measurement system. Also, the birefringence of ferro-fluid in the range from 0 to 29.48 mT was obtained equal to 0-3.510-4. This structure has great potential in the optical sensing area and biomedical applications as drug delivery.
Type of Study:
Research |
Subject:
Special